Quality Inspection Report: DXT15030-06 Adjustable Permanent Magnet

Home    Dexinmag News    Permanent Magnet    Quality Inspection Report: DXT15030-06 Adjustable Permanent Magnet

lateral view of DXT15030-06 Adjustable Permanent Magnet DXT15030-06 Adjustable Permanent Magnet Pole magnetic field of DXT15030-06 Adjustable Permanent Magnet

 

Overall Dimensions: 520mm(L) x 460mm(W) x 940mm(H)

 

Pole face diameter: 150mm

Air gap range: 10-100 mm

Weight: 176kg

 

Performance test report
 Introduction
    1. Test purpose
Through the analysis of the test results, the evaluation of the product performance is obtained;
Evaluate whether the test product meets the technical requirements;
Provide reference data for product design and after-sales service, and provide a strong basis for leaving the factory.
    2. Basic information
 Product Name:
Adjustable permanent magnet
Product model: DXT15030-06
Test time: May. 05, 2024
    3. Testing environment
The detection environment is closer to the actual environmental conditions used by the user, including factors such as lead wire length and ambient temperature. The time is selected in the time interval where the fluctuation of the geomagnetic field is small. Before the test, the instruments required for the test were turned on and warmed up in advance and the measurement environment was recorded, as shown in Table 1.
Measurement environment
Environment temperature Product initial temperature Lead length Environmental magnetic field
5.0℃ 5.0℃ - 0~30000nT
Table 1 Measurement environment data
 
Magnetic field parameter test
    1. Using the device
DX-180 Gauss Meter
    2. Magnetic field measurement
This product uses the following measurement methods:
Fixed-point measurement: measure the magnetic field at the target point
Magnetic field strength
Air Gap Display current (A) Display voltage Voltage (V) Magnetic field
strength(T)
10mmGap - - 0.896
20mmGap - - 0.733
30mmGap - - 0.625
40mmGap - - 0.544
50mmGap - - 0.485
60mmGap - - 0.435
70mmGap - - 0.394
80mmGap - - 0.359
90mmGap - - 0.327
100mmGap - - 0.301
Table 2 Magnetic field strength data
Note: When the lower electrode sample stage is not installed and the upper electrode scale is 25mm, the actual air gap is 30mmGap.
 
Conclusion
The magnetic field and electrical performance of the product meet the requirements of the corresponding technical parameters. The final performance of the product is subject to this document.