DXWDS-130 Water-cooled C Frame Electromagnet: Quality Inspection Report

Home  ꄲ  Dexinmag News  ꄲ  Electromagnet  ꄲ  DXWDS-130 Water-cooled C Frame Electromagnet: Quality Inspection Report

DXWDS-130 Water-cooled C Frame Electromagnet p1 DXWDS-130 Water-cooled C Frame Electromagnet p2 DXWDS-130 Water-cooled C Frame Electromagnet p3

 

I. Basic Information

Equipment Name: Water-cooled C Frame Electromagnet

Equipment Model: DXWDS-130

 

II. Mechanical Dimensions

Overall Dimensions:
Length * Width * Height
1030 mm * 470 mm * 450 mm

 

III. Packing List

Name Specifications Quantity
Water-cooled C Frame Electromagnet DXWDS-130

1

Power Connection Cable

-

1

Flexible connection - 2
PT100 Wire

-

1

probe holder

-

1

Grounding Wire

-

1

Certificate of Conformity

-

1

Test Report

-

1

 

IV. Packaging Type
Wooden Box

 

V. Packaging Filler
Foam Board

 

VI. Labeling
Product Nameplate

 

VII. Total Weight
408.7kg

 

 

 

Performance test report
 Introduction
    1. Test purpose
Through the analysis of the test results, the evaluation of the product performance is obtained;
Evaluate whether the test product meets the technical requirements;
Provide reference data for product design and after-sales service, and provide a strong basis for leaving the factory.
    2. Basic information
 Product Name:
water-cooled electromagnet
Product model: DXWDS-130
Test time: 20261110-439
    3. Testing environment
The detection environment is closer to the actual environmental conditions used by the user, including factors such as lead wire length and ambient temperature. The time is selected in the time interval where the fluctuation of the geomagnetic field is small. Before the test, the instruments required for the test were turned on and warmed up in advance and the measurement environment was recorded, as shown in Table 1.
Measurement environment
Environment
temperature
Product initial
temperature
Lead length Environmental
magnetic field
13.0℃ 13.0℃ - 0~30000nT
Table 1 Measurement environment data
 
Magnetic field parameter test
    1. Using the device
DX-F2031 power supply
DX-180 Gauss Meter
DXACP Power Amplifier
    2. Magnetic field measurement
This product uses the following measurement methods:
Fixed-point measurement: measure the magnetic field at the target point
Magnetic field strength
No.

Current

(A)

Voltage

(V)

Power

(W)

Magnetic field
strength(Gs)
DXWDS-130 50mmGap Central Magnetic Field 2.5 5.50 13 967.97
5.0 11.00 55 1914.71
7.5 16.45 124 2862.29
10.0 22.01 222 3816.90
12.5 27.58 346 4772.10
15.0 33.24 499 5734.40
17.5 38.79 680 6656.60
20.0 44.34 887 7545.10
22.5 49.92 1125 8380.20
25.0 55.58 1391 9120.40
27.5 61.28 1687 9784.60
30.0 66.98 2011 10326.70
32.5 72.79 2368 10813.10
35.0 78.66 2756 11240.90
36.0 81.08 2921 11408.20
Table 2 Magnetic field strength data
 
Electrical parameter test
    1. Using equipment
Digital multimeter
Impedance analyzer
    2. Test method
The digital instrument with bridge circuit and voltammetry is used for measurement. The measurement results are shown in the table below.
Resistance R measurement
Environment temperature Product temperature Measuring resistance ResistanceR@20℃ ResistanceR@85℃
13.0℃ 13.0℃ 2.208Ω 2.281Ω 2.964Ω
Table 3 Resistance R data
 
Temperature rise test
This product uses the following measurement methods:

a. Using magnetic field temperature rise measurement: given the limit working time and maximum temperature under the target magnetic field current required by the user.

b. Maximum current temperature rise measurement: Measure the ultimate working time and maximum temperature under the maximum safe current that the product can withstand

c. Measure the data on temperature, time and current of the entire coil. The measurement results are shown in the table below.

Temperature rise test
Current[A] orking time[min] Temperature [℃]
30 0 11.0
5 20.4
10 28.1
15 34.4
20 39.3
25 42.4
30 44.8
35 46.7
40 48.0
45 48.7
50 49.5
55 50.0
60 50.5
65 50.5
70 50.9
75 50.9
80 50.9
85 51.0
90 51.3
95 51.2
100 51.5
105 51.4
110 51.3
115 51.4
120 51.3
Note When water-cooled, the electromagnet reaches thermal equilibrium after 120 minutes; at this point, the current is 30 A, the voltage is 77.19 V, and the power is 2317 W.
Table 4 Relationship data between temperature, working time and current
 
Conclusion
The magnetic field and electrical performance of the product meet the requirements of the corresponding technical parameters. The final performance of the product is subject to this document.